- Home
- Services/IndustriesServicesindustries
- About Us
- LocationsStatesAccordion ContentAccordion ContentAccordion ContentAccordion Content
- Job Openings
- Quick Links
- ATS Family
DMM Calibration
Periodic DMM calibration from Applied Technical Services helps to maintain measurement accuracy and quality. The ATS calibration lab has provided services since 1987. We know how irreplaceable benchtop and handheld digital multimeters are to electricians, HVAC technicians, and professionals in power generation and other industrial fields. Our calibration experts work fastidiously to provide clients with a quick turnaround rate of 7 to 10 business days.
Operation in rugged conditions or with high electrical loads can wear down multimeter components and require repairs or calibration. Most equipment manufacturers recommend yearly calibrations for regulatory compliance and as a good maintenance practice, though devices with more extreme operating requirements may need more frequent calibrations. Users should also submit DMMs for calibration after an accident or damage.
Why ATS?
ATS is A2LA-accredited in a broad range of calibration services for handheld and benchtop instruments. Our calibration lab accepts multimeters with up to 8 digits. Before calibrating any instrument, our experts closely inspect the device for signs of flaws or damage. If the device has damage, our technicians contact the client to discuss repairs before proceeding.
We calibrate for multiple critical functions:
- AC/DC voltage
- Resistance
- Current
- Frequency
- Capacitance
To calibrate a multimeter, our experts compare the device’s readings at multiple test points with a precise calibration instrument from our lab. If the client’s device returns measurements outside the acceptable tolerances, our experts adjust the multimeter to restore NIST traceability. Unless requested otherwise, ATS technicians follow documented calibration procedures and tolerances recommended by the multimeter’s manufacturer.
Certificates of Calibration
Our calibration experts summarize their services in a certificate of calibration that includes the as-found and as-left data, the standard used during the calibration procedure, and the relation to NIST values. We keep all calibration reports on iPortal, our web-based interface that provides clients with secure 24/7 access to downloadable and printable copies of past certificates, device histories, and calibration statuses.
Calibration Lab Controls
The ATS calibration lab undergoes an annual assessment to ensure operations meet industry-wide conditions for ISO 17025 recertification. We are currently certified to perform A2LA-accredited calibrations with the following capabilities:
- AC current: up to 100 kHz
- AC voltage: 1 Hz to 1 MHz
- Capacitance: <10 pF to 1120 µF
- DC current: 10 µA to 10 kA
- DC voltage: 0 mV to 240 kV
- Resistance: 0 Ω to 1 GΩ
We keep our lab under stable conditions to limit the effects of environmental fluctuations. The temperatures remain within 2 degrees of 68 ˚ C and relative humidity 30-55% RH. Additionally, our floors have isolation joints to dampen vibrations as experts conduct operations.
Common DMM Manufacturers and Models
If you cannot find your device here, call +1 (888) 287-5227 to speak with our representatives.
Meet the Applied Technical Services Family
We are a consulting engineering, calibration, inspection, and testing company with an expanding Family of Companies (FoC) serving national and international clients. Our ISO 9001:2015-registered Quality Management System oversees the continual optimization of our processes as we grow our FoC and open new locations. In addition to calibration, ATS is ISO/IEC 17025 accredited in electrical, chemical, nondestructive, and mechanical tests in the field and dedicated labs.
ATS services comply with the following:
- 10 CFR Part 21
- 10 CFR 50 – Appendix B
- ANSI/NCSL Z540-1
Contact Us
Submit the form on this page to request calibration of your digital multimeter from our seasoned experts. If you have any questions about how our capabilities can meet your needs, please call +1 (888) 287-5227 to speak with our representatives.
Request Form
"*" indicates required fields
Electrical Calibration Links
- Capacitance Meters
- Clamp Meter Calibration
- Data Acquisition Calibrations
- Decade Box Calibration
- DMM Calibration
- Electronic Calibration Lab
- Electronic Scale Calibration
- Embedded Calibration Lab
- Extech Easyview Light Meter Calibrations
- Extech Light Meter Calibrations
- Fluke 289 Calibration
- Frequency Counter Calibration
- Fuel Meter Calibration Services
- Function Generator Calibration
- Greenlee Light Meter Calibration
- Gauss Meter Calibration
- Hipot Tester Calibration
- Insulation Tester Calibration
- LCR Meter Calibration
- Light Meter Calibrations
- Megger Calibrations
- Multimeter Calibration
- Multimeter Calibration Service
- Narda Calibration
- Network Analyzer Calibration
- Noise Dosimeter Calibration
- Oscilloscope Calibration
- Radiometer Calibrations
- Shunt Calibration
- Signal Generators Calibration
- Sound Level Meter Calibration Services
- Spark Tester Calibration
- Spectrophometer Calibration Services
- Spectrum Analyzer Calibration
- Stopwatch Calibration
- Tachometer Calibration
- Timer Calibration
- UV Meter Calibration
- UVP J221 Black Light Meter Calibrations
- Watt-Meter Calibration