The Applied Technical Services Family of Companies performs high potential testing, also known as Hipot Testing, to help avoid electric shock, fire, and other potential motor hazards.
High Potential Testing
Hipot Testing is a term commonly used to refer to Dielectric Withstand Testing, a test that applies high voltage to machinery, equipment, and devices to analyze electrical insulation. Hipot testing motors helps to prevent various hazards that can result in serious harm to individuals as well as damage to connected and nearby equipment. The testing procedure for Hipot testing motors typically consists of the following steps:
Test Preparation: the motor is completely disconnected from all accessories and power sources and a solid ground is verified. All specialized tools and equipment, such as power supplies, dielectric withstand testers, and any other testing devices are prepared. Testing parameters are established to determine the optimal test voltage, typically aligning with regulatory standards, safety regulations, motor specifications, and/or client-specified parameters.
Voltage Induction: high voltage is applied to the motor’s insulation system for a predetermined duration. Any potential voltage leaks are identified at this step in the process and data is compiled.
Data Analysis: Our highly skilled Hipot testing experts thoroughly analyze all data from the test to determine the condition and effectiveness of the motor’s insulation.
Documentation: All ATS testing procedures consist of thorough, in-depth reporting covering every aspect of preparation, testing, final findings, and recommended action.
Test Preparation: the motor is completely disconnected from all accessories and power sources and a solid ground is verified. All specialized tools and equipment, such as power supplies, dielectric withstand testers, and any other testing devices are prepared. Testing parameters are established to determine the optimal test voltage, typically aligning with regulatory standards, safety regulations, motor specifications, and/or client-specified parameters.
Voltage Induction: high voltage is applied to the motor’s insulation system for a predetermined duration. Any potential voltage leaks are identified at this step in the process and data is compiled.
Data Analysis: Our highly skilled Hipot testing experts thoroughly analyze all data from the test to determine the condition and effectiveness of the motor’s insulation.
Documentation: All ATS testing procedures consist of thorough, in-depth reporting covering every aspect of preparation, testing, final findings, and recommended action.
Applied Technical Services
Our highly advanced electrical testing laboratory is staffed by industry-leading experts with decades of combined experience. We perform electrical testing for businesses and organizations operating in the aviation, lighting, metal, power generation, manufacturing, consumer electronics, aerospace, power generation, and automotive industries, as well as several others. ATS tests to standards established by organizations including but not limited to the IEC, ANSI, IEEE, ASTM, and MIL-STD, is ISO 17025 accredited in electrical testing, and adheres to the standards of our ISO 9001:2015 registered quality management system. Here at ATS, we understand the importance of high-quality, reliable service with short turnaround times. We offer expedited service on several of our electrical testing offerings and work diligently to keep your business operations uninterrupted. For more information or a free quote, submit a request form on this page or give us a call at 1 (888) 287-5227.
Request Form
"*" indicates required fields
Electrical Testing
- AC Hipot Testing
- AC and DC HiPot Testing
- Battery Testing
- Battery Electrical Testing
- Battery Chemical Analysis
- Battery Pack Testing
- Bus Bar Hipot Testing
- Conductivity ASTM B193
- Conductivity ASTM B193 testing
- Contact Resistance MIL DTL 5541 Testing
- DC Hipot Cable Testing
- DC Hipot Testing
- DC Hipot Testing of Medium Voltage Cables
- Dielectric Breakdown Testing
- Dielectric Constant Testing
- Dielectric Constant ASTM D150 Testing
- Dielectric Strength ASTM D149 Testing
- Dielectric Strength Testing
- Dielectric Withstand Testing
- Dielectric Withstand Voltage Test
- DWV Electrical Test
- DWV Testing
- Electrical Testing EV Batteries
- Electrical Lab Services
- Electrical Testing Lab
- Electrical Testing Laboratory
- Electronic Product Testing
- EV Battery Testing
- EV Battery Thermal Testing
- HiPot Cable Testing
- HiPot Testing
- Hipot Testing Motors
- HiPot Testing Services
- Lithium Ion Battery Testing
- IEC 60502-2 Hipot Test
- IEC 60950 Hipot Test
- IEC 60950 Testing
- Insulation Resistant Testing
- Insulation Resistant quote request form
- SAE J1455 Recommended Environmental Practice for Heavy Trucks
- SAE J2464 Testing
- SAE J2464 Electric and Hybrid Electric Vehicle Rechargeable Energy Storage (RESS) Safety and Abuse Testing
- Soil Resistivity Testing
- Thermal Testing EV Batteries
- Voltage Drop Testing