Current query: Array ( [calibration] => balance-calibrations [post_type] => calibration [name] => balance-calibrations [calibration-category] => mechanical-equipment [error] => [m] => [p] => 0 [post_parent] => [subpost] => [subpost_id] => [attachment] => [attachment_id] => 0 [pagename] => [page_id] => 0 [second] => [minute] => [hour] => [day] => 0 [monthnum] => 0 [year] => 0 [w] => 0 [category_name] => [tag] => [cat] => [tag_id] => [author] => [author_name] => [feed] => [tb] => [paged] => 0 [meta_key] => [meta_value] => [preview] => [s] => [sentence] => [title] => [fields] => all [menu_order] => [embed] => [category__in] => Array ( ) [category__not_in] => Array ( ) [category__and] => Array ( ) [post__in] => Array ( ) [post__not_in] => Array ( ) [post_name__in] => Array ( ) [tag__in] => Array ( ) [tag__not_in] => Array ( ) [tag__and] => Array ( ) [tag_slug__in] => Array ( ) [tag_slug__and] => Array ( ) [post_parent__in] => Array ( ) [post_parent__not_in] => Array ( ) [author__in] => Array ( ) [author__not_in] => Array ( ) [search_columns] => Array ( ) [ignore_sticky_posts] => [suppress_filters] => [cache_results] => 1 [update_post_term_cache] => 1 [update_menu_item_cache] => [lazy_load_term_meta] => 1 [update_post_meta_cache] => 1 [posts_per_page] => 8 [nopaging] => [comments_per_page] => 50 [no_found_rows] => [order] => DESC )

At Applied Technical Services, we provide on-site or in-lab balance calibrations to ensure your weighing device measures properly and yields accurate results. Our mechanical calibration labs are well-equipped with modern technology and experienced staff.

Balance calibration is necessary for preventing the natural performance decline that arises from normal use over time. As repeated usage may slowly diminish a balanceโ€™s efficiency, the accuracy of a balance or scale begins to deteriorate, and results become less accurate.

It is vitally important to ensure your device is regularly maintained. Routinely schedule calibrations to preserve the precision of your balance and ensure that your device adheres to established quality requirements.

Calibration Capabilities

  • Calibration Weight Range โ€“ 0 to 1,200 lbs.

Types of Balances Calibrated at ATS

  • Equal Arm โ€“ An equal arm balance containing two platforms that are equidistant and separated by a pivot point, or fulcrum, that acts as the center of gravity, allowing for a measurement of โ€œzeroโ€ when both scales are maintained at an equal level.
  • Unequal Arm โ€“ The unequal arm balance is comprised of two platforms that are not equidistant from the fulcrum. One arm that holds the platform is shorter than the other. The object that is weighed is placed on the shorter arm, while weights are placed on the other arm until balance is achieved.
  • Spring โ€“ The spring balance consists of a coiled spring and a hook, relying on physics and the spring’s physical nature to calculate the weight of an object.
  • Top Loading โ€“ A top loading balance is one of the most common types of weight measurement tools used. This balance has a weight capacity ranging from 20 g to 64.1 kg. Most top loading balances include computer interface capabilities using USB ports, short response times, and security measures.
  • Portable โ€“ The portable balance is commonly used in field work for its convenience. Its durability, rapid response, and user-friendly interface make the portable balance an attractive option.
  • Analytical โ€“ Analytical balances are usually quite sensitive and tend to be used by trained personnel only. Due to their sensitive nature, they require regular analytical balance calibration and maintenance.
  • Semi-Microbalances and Microbalances โ€“ These balances are highly accurate and have weighing capabilities to one-hundredth of a milligram. The semi-microbalances and microbalances are used for specialized purposes such as the measurement of paint coatings or weighing sensitive, chemical samples.

Verified Weight Classes Used by ATS

  • ANSI/ASTM Class F
  • ANSI/ASTM Class 4
  • ANSI/ASTM Class 3
  • ANSI/ASTM Class 2
  • ANSI/ASTM Class 1
  • A&D
  • Adam Equipment
  • Avery Weight
  • Mettler-Toledo
  • Ohaus
  • Pennsylvania
  • Setra

Our Focus on Customer Service

Serving clients locally, nationally, and globally, the satisfaction of our clientsโ€™ needs is our priority. We continue to practice reliability, accuracy, and convenience to build on our reputation as a leading calibration, testing, and inspection provider. We promise quick turnaround times of 5-7 business days and friendly, responsive customer service.

ATS Quality Assurance

Our calibration lab is ISO/IEC 17025:2017-accredited to perform a wide range of calibration services. We perform calibrations in accordance with documented and standard procedures, restoring metrological precision and NIST traceability to your equipment.

All our calibrations comply with applicable standard quality requirements. We also comply with regulations and standards such as the following: ISO 9001:2015-2015, 10 CFR 50 – Appendix B, ANSI/NCSL Z540-1, and 10 CFR Part 21.

Contact Us

If you have equipment that needs calibration, call +1 (888) 287-5227 or click here to request our services. For more information on our balance calibration services, please do not hesitate to contact us today!

Customer Service Representative, Ready to Help Direct You to the People Who can Help

We’re here to help.

Our 5 Major Segments

Testing

Inspection

Calibration

Engineering

Forensics

image of United States with dots indicating locations of ATS Branches and Acquisition Companies

Stay ahead of the curve with ATS insights

Unlock exclusive industry insights, expert tips, and the latest updates from ATS by subscribing to our newsletter. Join thousands of professionals who trust ATS to keep them informed and inspired.

This field is for validation purposes and should be left unchanged.