Current query: Array ( [standard] => astm-e2248-testing [post_type] => standard [name] => astm-e2248-testing [standard-category] => american-society-for-testing-and-materials [error] => [m] => [p] => 0 [post_parent] => [subpost] => [subpost_id] => [attachment] => [attachment_id] => 0 [pagename] => [page_id] => 0 [second] => [minute] => [hour] => [day] => 0 [monthnum] => 0 [year] => 0 [w] => 0 [category_name] => [tag] => [cat] => [tag_id] => [author] => [author_name] => [feed] => [tb] => [paged] => 0 [meta_key] => [meta_value] => [preview] => [s] => [sentence] => [title] => [fields] => all [menu_order] => [embed] => [category__in] => Array ( ) [category__not_in] => Array ( ) [category__and] => Array ( ) [post__in] => Array ( ) [post__not_in] => Array ( ) [post_name__in] => Array ( ) [tag__in] => Array ( ) [tag__not_in] => Array ( ) [tag__and] => Array ( ) [tag_slug__in] => Array ( ) [tag_slug__and] => Array ( ) [post_parent__in] => Array ( ) [post_parent__not_in] => Array ( ) [author__in] => Array ( ) [author__not_in] => Array ( ) [search_columns] => Array ( ) [ignore_sticky_posts] => [suppress_filters] => [cache_results] => 1 [update_post_term_cache] => 1 [update_menu_item_cache] => [lazy_load_term_meta] => 1 [update_post_meta_cache] => 1 [posts_per_page] => 8 [nopaging] => [comments_per_page] => 50 [no_found_rows] => [order] => DESC )

The Applied Technical Services Family of Companies (ATS FoC) performs Charpy impact testing according to ASTM E2248, using Miniaturized Charpy V-Notch (MCVN) specimens to evaluate the impact properties of metallic materials. ASTM E2248 outlines requirements for specimen sampling, preparation, equipment, calibration, testing procedures, and data reporting. MCVN testing is suitable when standard Charpy V-notch specimens are not feasible due to limited material, thin products, or the need to extract specimens from existing components.

What Nuclear Materials and Components Can ASTM E2248 Testing Evaluate?

ASTM E2248 testing allows characterization of metallic materials in nuclear applications where only small or limited-volume specimens are available. Nuclear manufacturers, operators, and research organizations use MCVN testing to evaluate materials in reactor components, piping, pressure-boundary materials, weldments, surveillance capsules, and in-service components. The method accommodates specimens from thin product forms, previously tested materials, and material extracted from in-service components. This approach helps organizations assess material behavior while conserving valuable material for further analysis or testing.

About Our Laboratory ASTM E2248 Testing Services

Our laboratory offers technical expertise, dedicated customer service, and strict quality practices to support complex materials testing programs. Our experienced staff collaborate with clients to define project requirements, oversee precise specimen preparation and testing, and ensure clear communication throughout each phase. We maintain relevant accreditations and quality systems, delivering reliable results supported by technical competence, equipment controls, documentation, and standardized test procedures. We are ready to support nuclear industry projects that require tightly controlled mechanical testing and consistent, dependable results.

Can ASTM E2248 Testing Support Nuclear Quality Assurance Programs?

ASTM E2248 testing provides essential mechanical-property data for nuclear material characterization, research, component evaluations, and quality-assurance activities when project requirements specify or permit MCVN impact testing. E2248 defines requirements for equipment, specimen preparation, sampling, testing, and precision and bias, enabling laboratories to use a consistent methodology for comparable impact measurements. However, project teams must determine if MCVN data meet their specific nuclear qualification or engineering requirements. ASTM E2248 does not specify how MCVN results should be correlated with conventional Charpy data or applied to ferritic-material evaluations.

Request Our Services

If your nuclear materials program requires impact testing of limited-volume specimens, our laboratory provides ASTM E2248 testing services tailored to your project needs. Contact us through our online form or call +1 (888) 287-5227 to consult with our technical team about your ASTM E2248 testing requirements.

Customer Service Representative, Ready to Help Direct You to the People Who can Help

We’re here to help.

Our 5 Major Segments

Testing

Inspection

Calibration

Engineering

Forensics

image of United States with dots indicating locations of ATS Branches and Acquisition Companies

Stay ahead of the curve with ATS insights

Unlock exclusive industry insights, expert tips, and the latest updates from ATS by subscribing to our newsletter. Join thousands of professionals who trust ATS to keep them informed and inspired.

This field is for validation purposes and should be left unchanged.